CPCSC Level 1: Build an Evidence File You Can Explain

A practical way for Canadian defence suppliers to connect cyber-hygiene controls to current records, owners, and contract scope.

Canonical HTML page

A folder full of screenshots can still leave a supplier unable to explain how its security controls work. The missing detail is often ordinary: which system the image came from, who checked it, whether it covers the contract’s information, and what happened after the picture was taken.

For suppliers subject to Canadian Program for Cyber Security Certification requirements, Level 1 evidence should make those connections easy to follow. Public Services and Procurement Canada’s Level 1 guidance describes a self-assessment against 13 cyber-hygiene controls and gives examples of records suppliers can keep.

Draw the boundary before collecting records

Start with the solicitation and contract. Identify the specified information, then trace where it is received, stored, processed, and shared. Include the people, endpoints, cloud services, and physical locations that can reach it. A security setting on a system outside that boundary tells you little about the information the contract requires you to protect.

The official guidance ties applicability and timing to contracting activity. Confirm the requirement with the contracting authority rather than treating a general program announcement as the schedule for a particular bid. If relying on recognition of a U.S. CMMC certification, obtain confirmation for the relevant scope; PSPC considers recognition case by case.

What an explainable record looks like

Examples of evidence, not a complete control mapping

PracticeUseful recordContext to retain
Access managementAccount list and access-review resultSystem, reviewer, removals and review date
Device managementCurrent device inventoryScope, owner and update process
Security awarenessTraining completion recordAudience, material and completion date
System protectionFirewall or MFA configurationRelevant service, scope and capture date
Recurring maintenanceUpdate or sanitization logWhat was done, by whom and when

One completed evidence-index row

Hypothetical record EV-03 covers a supplier’s contract-document workspace. PSPC Level 1 criteria identify control 03.01.01, Account management, and objective A.03.01.01.c.01: authorized system users are specified. This example addresses that objective only; it is not a complete control assessment or certification result.

EV-03 — controlled account-list evidence

Record fieldCompleted example
Scope and objectiveContract workspace CW-01 and its authorized user population; A.03.01.01.c.01. Other contract systems require their own coverage.
Evidence and captureControlled list ACL-CW01-v4, captured 15 October 2026; manager-approved roster ROSTER-4 and identity export IAM-4 are linked in the evidence index.
Reviewer and exceptionWorkspace owner reviewed the roster against IAM-4. A contractor account lacks current manager authorization; exception EX-02 remains open and access is suspended.
Decision and next reviewDo not mark the objective met while the discrepancy is unresolved. Identity administrator owns removal or documented authorization, followed by a fresh export and owner review on 16 October 2026; repeat on personnel/access changes.

A record can be simple. An access review might identify the account population, the manager who examined it, the exceptions found, and the date those exceptions were resolved. That tells a more useful story than a screenshot of the user-administration screen alone.

Avoid copying sensitive operational records into an unnecessarily broad evidence folder. Keep the evidence accessible to the people responsible for the assessment while preserving the access restrictions appropriate to its contents. A reference to a controlled source can be easier to maintain than several copies.

For every item: Record the control it supports, the system or location it covers, its owner, the capture date, and when it needs review. These are working practices for keeping evidence usable.

The attestation begins a maintenance cycle

Save the completed assessment, result and expiry information. PSPC’s retention guidance says evidence should be retained for the duration of the attestation cycle or at least one year. Assign responsibility for maintaining it through personnel changes, device replacement, and changes to service providers.

Set review dates according to how quickly a record can become wrong. An account list may change much faster than an approved policy. When a control is incomplete, record the gap and resolve it through the applicable assessment process; an attractive evidence pack cannot substitute for implementation.

A useful final check is to ask someone who did not assemble the folder to follow one control. Can they identify the requirement, the systems covered, the evidence of operation, and the owner who can answer a question? If they can, the file is much more likely to remain useful after the assessment is submitted.

Review the evidence behind a security decision

Cybersecurity risk advisory can help examine scope, evidence gaps and ownership before a contract decision.